Analysis of Building Frame: Introduction to Portal Method (Lecture 01)

The Portal Method is suitable for building which has a low elevation and uniform framing. The frames are considered to be a cantilever as they are fixed in the bottom. Moreover, to analyze the building frames using the portal method require following assumptions. 
              01. A hinge is placed at the center of each girder, since this is assumed to be a point of zero   moment.
              02. A hinge is placed at the center of each column, since this is assumed to be a point of zero   moment. 
                03. At a given floor level the shear of the interior column hinges is twice that at the exterior column hinges, since the frame is considered to be a super position of portals.   
Figure 01: A simple frame
Figure 02: Application of assumption 03:the shear of the interior column hinges is twice that at the exterior column hinges

No comments :

Post a Comment